IMPLANTANT-ABATMENT ULANISHINING TURLI XILLARIDA MIKRO-SUVNING SAQLASH DARAJASINI BAHOLASH

##article.authors##

  • Shomurodov Qahramon Erkinovich
  • Qurmayev Saidbek Ildar o'g'li

##article.subject##:

dental implantatsiya, implantant-abatment ulanishi, bakterial invaziya, Morze konusi, mikro-suvning saqlanishi

##article.abstract##

Tadqiqotda eksperimental model yaratish orqali turli xil ulanish turlari bilan "implantant-abatment" ulanishining germetikligi o'rganildi. Dental implantantlarning ichki interfaysining mikrob kontaminatsiyasining miqdoriy baholanishi o'tkazildi. Bakterial invaziyaning eng yuqori darajasi ichki oltiburchakli ulanishga ega bo'lgan dental implantantlarda aniqlandi, eng kam ko'rsatkichlar esa Morze konusi tipidagi ichki ulanishga ega bo'lgan dental implantantlarda kuzatildi.

Библиографические ссылки

Akula SKJ, Ramakrishnan H, Sivaprakasam AN. Comparative evaluation of the microbial leakage at two different implant-abutment interfaces using a new sealant. J Dent Implant Res 2021;40:35–47.

Bittencourt A, Neto C, Penitente PA, Pellizzer EP, Dos Santos DM, Goiato MC. Comparison of the Morse Cone connection with the internal hexagon and external hexagon connections based on microleakage – review. Prague Med Rep. 2021;122(3):181-90.

Fernandes, P.F.; Grenho, L.; Fernandes, M.H.; Sampaio-Fernandes, J.C.; Gomes, P.S. Microgap and bacterial microleakage during the osseointegration period: An in vitro assessment of the cover screw and healing abutment in a platform-switched implant system. J. Prosthet. Dent. 2021, 1–9.

Siadat H, Arshad M, Mahgoli HA, Fallahi B. Microleakage evaluation at implant-abutment interface using radiotracer technique. J Dent. 2016;13(3):176–83.

Yu P, Zhi L, Tan X, Yu H. Effect of sealing gel on the microleakage resistance and mechanical behavior during dynamic loading of 3 implant systems. J Prosthet Dent. 2020;127(2):308-17.

Shomurodov, K., Mirkhusanova, R., & Mikhalchenko, D. (2024). Effect of Laser Patterned Microcoagulation on Keratinized Mucosa Width and Gingival Thickness Around Dental Implants. Malaysian Journal of Medicine & Health Sciences, 20(6).

Shomurodov, K., & Mirkhusanova, R. (2023). Application of the soft tissue expanding technique before guided bone regeneration of an atrophic alveolar ridge. Journal of Health and Translational Medicine (JUMMEC), 26(1), 170-178.

Shomurodov, K., & Mirkhusanova, R. (2024). Comparative Evaluation of Soft Tissue Reaction to Titanium and Polyetheretherketone Customized Healing Abutments: a Split-Mouth Randomised Clinical Trial. Galician Medical Journal, 31(4).

Shomurodov, K. E., Mirkhusanova, R. S., & Jurakulov, N. S. (2023). The importance of keratinized gingiva in prosthetics on dental implants and methods of increasing its width (literature review). Integrative dentistry and maxillofacial surgery, 2(1), 82-89.

Yu P, Zhi L, Tan X, Yu H. Effect of sealing gel on the microleakage resistance and mechanical behavior during dynamic loading of 3 implant systems. J Prosthet Dent. 2020;127(2):308-17.

Загрузки

##submissions.published##

2025-08-30